Configuring Dial Services
7-18
114062 Rev. A
3.
Select the Port Application mode for this line, referring to the parameter
description that follows, and click on OK.
You return to the Configuration Manager window.
To continue, refer to “Creating Line Pools with ISDN Interf
aces” on page 7-38.
BRI Port Application Parameter
Use the following description as a guideline when you configure the Port
Application Mode.
Parameter: Port Application Mode
Default: Dialup – 2B+D
Options: Dialup – 2B+D
|
Dialup – 1B + D
|
Dialup – Floating B (AN only)
|
Leased – 2X64K
|
Leased – 1X64K
|
Leased – 128K
Function: Determines how the BRI interface operates. The options are
Dialup – 2B+D: Specifies that this is an ISDN switched line that provides
two B channels, and call setup is done between the router and an ISDN
switch.
Dialup – 1B + D: Specifies that this is an ISDN switched line that
provides only one B channel, and call setup is done between the router
and an ISDN switch. Use this option when you do not need to use two B
channels.
Dialup – Floating B: This option is available only on BayStack AN and
ANH routers. It specifies that although this is an ISDN switched line that
provides two B channels, the software makes the necessary adjustments if
only one channel is in use. Use this option if you can only purchase
2B + D service, but only want to use one B channel, or your application
requires two synchronous ports and only one B channel. Refer to
Chapter 3 for more information.