Avaya Configuring WAN Lines Services Manuel d'utilisateur Page 405

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 462
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 404
BCC show Commands
308648-14.00 Rev 00
B-19
show ft1e1 fdl-att
The
show ft1e1 fdl-att
command displays the Facility Data Link (FDL) error
statistics. This command shows information only for FT1.
The output contains the following information:
Slot/Connector Name of the physical interface.
Line Number Number assigned to this line.
ES Counts Number of erroneous seconds.
SES Counts Number of severely erroneous seconds.
SEFS Counts Number of severely erroneous framing seconds encountered by a
DS1 interface in the current 15 minute interval.
UAS Counts Number of unavailable seconds.
CSS Counts Number of controlled slip seconds (CSS) encountered by a DS1
interface in the current 15 minute interval.
PVC Counts Number of path coding violations (PVC) encountered by a DS1
interface in the current 15 minute interval.
LES Counts Number of line erroneous seconds (LES) encountered by a DS1
interface in the current 15 minute interval.
BES Counts Number of bursty erroneous seconds (BESs) encountered by a
DS1 interface in the current 15 minute interval.
DM Counts Number of degraded minutes (DMs) encountered by a DS1
interface in the current 15 minute interval.
LCV Counts Number of line code violations (LCVs) encountered by a DS1
interface in the current 15 minute interval.
Vue de la page 404
1 2 ... 400 401 402 403 404 405 406 407 408 409 410 ... 461 462

Commentaires sur ces manuels

Pas de commentaire