Configuring WAN Line Services
9-22
308648-14.00 Rev 00
• Select NRZI for nonreturn to zero inverted coding.
• Select NRZI Mark for nonreturn to zero inverted mark coding.
Set the line coding for the interface.
Using the BCC
To set the synchronous line coding, navigate to the logical-line prompt (for
example,
box; fe1/1/1; logical-line/boston) and type:
sync-line-coding
variable
For example:
logical-line/boston#
sync-line-coding nrz
Using Site Manager
See the Sync Line Coding parameter on page A-68 for information.
Enabling or Disabling Extended Addressing
By default, the router does not test the address length of frames on a synchronous
interface. With the Extended Address parameter enabled, the router tests the first
bit of the address to determine the length of the address, in octets.
Enable or disable extended addressing for the interface.
Using the BCC
To enable or disable extended addressing, navigate to the logical-line prompt (for
example,
box; fe1/1/1; logical-line/boston) and type:
extended-address
variable
For example:
logical-line/boston#
extended-address disabled
Using Site Manager
See the Extended Address parameter on page A-68 for information.