Configuring WAN Line Services
8-18
308648-14.00 Rev 00
Setting the Secondary Clock Source
The Secondary Clock parameter identifies the secondary source of the timing
signals. The router uses the secondary clock only when the primary clock is
unavailable.
Table 8-11
lists the options for this parameter.
Using the BCC
To set the secondary clock, navigate to the ft1 prompt (for example,
box
;
ft1/1/1
)
and type:
secondary-clock
variable
For example:
ft1/1/1#
secondary-clock loop1
Using Site Manager
See the Secondary Clock parameter on page A-48 for information.
Table 8-11. Secondary Clock Options
BCC Options Site Manager Options Description
internal Internal The default; uses the clock chip on the link
or net module
loop1 Port 1 Ext Loop Uses the signal coming from port 1
Vue de la page 219