Avaya Configuring WAN Lines Services Manuel d'utilisateur Page 215

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 462
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 214
Configuring FT1 Services
308648-14.00 Rev 00
8-13
Using Site Manager
See the Accept Loopback Request parameter on page A-48 for information.
When you enable Accept Loopback Request, you can set the type of loopback you
want. See “Setting a Loopback Configuration” on page 8-14
.
Setting the Loop Retention Interframe Time Fill
In the BCC, the FDL Loop Interframe Fill parameter is set to mark by default,
which enables the detection of loop retention code when the remote end is in line
or payload loopback. When you set this parameter to loop-retention, the loop
retention interframe time fill (IFTF) for the facility data link (FDL) is enabled
after it sends loop-up code.
Using the BCC
To set this parameter, navigate to the ft1 prompt (for example,
box
;
ft1/1/1
) and
type:
fdl-loop-interframe-timefill
variable
For example:
ft1/1/1#
fdl-loop-interframe-fill loop-retention