Configuring FT1 Services
308648-14.00 Rev 00
8-31
Configuring BERT Diagnostic Pattern Tests
FT1 link modules support the bit error rate test (BERT) on individual logical lines.
You can enable or disable BERT mode using Site Manager only.
In BERT mode, the router introduces deliberate error patterns into the transmitted
bit stream on a single logical line. It can generate patterns such as all ones, all
zeros, or a quasi-random signal sequence (QRSS) pattern.
Using Site Manager
To enable BERT mode and specify the BERT diagnostic test pattern, complete the
following tasks.
For more information about running BERT diagnostics, see “Testing FT1 Lines”
on page 8-35
.
Site Manager Procedure
You do this System responds
1. Enable
BERT Mode
on the FT1 logical
line.
Click on
Help
or see the parameter
description on page A-54 for information.
Site Manager enables BERT mode.
2. Specify the bit pattern transmitted during
BERT diagnostics.
Click on
Help
or see the
BERT Test
Pattern
parameter on page A-54 for
information.
Site Manager specifies the bit pattern.