Configuring ATM Services
9-24
Parameter: No Response Timer
Default: 70
Range: 1 to 120
Function: Defines the SSCOP No Response timer value (in tenths of a second). This
value sets the allowable time between the receipt of STAT PDUs.
So as not to interrupt the flow of data, the SSCOP does not require a reply
to every Poll PDU. This can cause problems in detecting a broken
connection. To alleviate this problem, the No Response timer runs parallel
to the Poll timer. If both the No Response timer and the Poll timer expire,
the SSCOP clears the connection.
The No Response timer value must equal at least the sum of the Keep
Alive timer plus the length of one round-trip delay.
Instructions: Accept the default, 70, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.11
Parameter: Connection Control Timer
Default: 10
Range: 1 to 120
Function: Defines the SSCOP Connection Control (CC) timer value (in tenths of a
second). This value sets the allowable time between the transmission of
BGN, END, Resynchronization (RS), and Error Recovery (ER) PDUs, as
long as the sender has not received an acknowledgment to any of these
PDUs.
The CC timer must equal at least the length of one round-trip delay.
Instructions: Accept the default, 10, or enter a value from 1 to 120.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.8.1.12