Editing ATM Signaling and ILMI Parameters
9-5
Parameter: Max Point to Point Connections
Default: 1000
Range: 0 to 32767
Function: Identifies the maximum number of simultaneous point-to-point
connections allowed for this circuit.
Instructions: Accept the default, 1000, or enter a value from 0 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.7
Parameter: Max Point to Multipoint Connections
Default: 40
Range: 0 to 32767
Function: Identifies the maximum number of simultaneous point-to-multipoint
connections allowed for this circuit.
Instructions: Accept the default, 40, or enter a value from 0 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.8
Parameter: Max Parties in Multipoint Connections
Default: 1
Range: 0 to 32767
Function: Identifies the maximum number of simultaneous parties in a point-to-
multipoint connection allowed for this circuit.
Instructions: Accept the default, 1, or enter a value from 0 to 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.9