3 Translating the IPSIs
Administering the IPSIs
48 Installing and Configuring the Avaya S8700 or S8710 Media Server
June 2004
Setting alarm activation level
1 Type change system-parameters maintenance and press Enter.
2 In the CPE Alarm Activation Level field, select none (default), warning, minor, or major,
depending on the level the customer wants and press
Enter to effect the changes.
3 Repeat for each IPSI.
Installing the translation file
1 Type save translations and press Enter to save the translations to the hard drive.
change system-parameters maintenance Page 1 of 3
MAINTENANCE-RELATED SYSTEM PARAMETERS
OPERATIONS SUPPORT PARAMETERS
CPE Alarm Activation Level: none
SCHEDULED MAINTENANCE
Start Time: 22 : 00
Stop Time: 06 : 00
Save Translation: daily
Update LSPs When Saving Translations: y
Command Time-out (hours): 2
Control Channel Interchange: no
System Clocks/IPSI Interchange: no