GeoTel Features User Manual NCD Alarm Messages
P0602482 Ver. 04.03 Avaya Page 437
NIC Clearing Loss of Secondary NIC
NIC Clearing Loss of data integrity on ATM
The following alarms usually occur during TMS startup. They may indicate:
insufficient memory
software fault
incorrect configuration
incompatibilities
hardware faults
Ethernet Health check failed for TMS in slot #
The NIC has detected a failure on the TCP/IP or ethernet health check of a
TMS. See “TMS Health Check” on page 443.
Power supply temperature for TMS in slot # is above low
threshold
The displayed power supply has exceeded the first temperature threshold. See
“Temperature” on page 442.
Power supply temperature for TMS in slot # is above high
threshold
The displayed power supply has exceeded the second temperature threshold.
Operating the system at these temperatures may cause permanent component
damage. Shut down the system. See “Temperature” on page 442.
Power supply current C1 for TMS in slot # is out of
tolerance, detecting current above 2.1 amp threshold
See “Current” on page 442.
Power supply current C2 for TMS in slot # is out of
tolerance, detecting current above 3.1 amp threshold
See “Current” on page 442.
Power supply current C3 for TMS in slot # is out of
tolerance, detecting current above 9 amp threshold
See “Current” on page 442.
Power supply current C4 for TMS in slot # is out of
tolerance, detecting current above 1 amp threshold
See “Current” on page 442.