VENGINE 25027
MESSAGE
[Para <block_name>/<1>] READPREV was requested for HSAM
dataset '<name>'
SEVERITY
3
PROBABLE CAUSE
The application tried to perform a "Previous" Browse Operation, specified in a Disk I/
O block, on an HSAM file. The "Previous" operation should be disabled by default if
the application accesses a valid HSAM file. If PeriProducer allowed a "Previous"
Browse Operation to be specified for an HSAM file, the database may be corrupt or
there may be more serious problems.
ACTION
Verify that the application accesses a valid Indexed file. If the application
accesses a non-indexed file, either specify an indexed file or do not use the
"Previous" Browse Operation.
Verify that the database is valid and error free.
If there are no problems with the database, contact Avaya technical support
for assistance.