Configuring SNMP, RMON, BootP, DHCP, and RARP Services
A-14 117362-A Rev. A
Parameter: Threshold Max Successive Alarms
Path: Configuration Manager > Protocols > Global Protocols > Thresholds >
Thresholds
Default: 5
Options: Any integer value
Function: Specifies the maximum number of successive alarms that the agent generates
for this variable. A successive alarm represents two or more polling periods
when the agent generates an alarm as a result of an exception at the same
threshold level.
Instructions: Specify the maximum number of successive alarms. When the agent exceeds the
maximum number of alarms, it marks the threshold as held. The agent generates
no more alarms until the variable either crosses the threshold at a different level
or crosses no threshold for the number of polling intervals equal to the value of
the Threshold HoldDown Intervals parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.6.2.1.14
Parameter: Threshold HoldDown Intervals
Path: Configuration Manager > Protocols > Global Protocols > Thresholds >
Thresholds
Default: 1
Options: Any integer value
Function: Specifies the number of exception-free polling intervals through which a
variable in a held state must pass before the variable is no longer considered
held.
Instructions: Specify the number of exception-free polling intervals. The lower the number
you select, the more likely the agent is to generate repetitive event messages for
a variable that is intermittently exceeding thresholds.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.6.2.1.15