Avaya Configuring Frame Relay Services Manuel d'utilisateur Page 175

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 240
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 174
Site Manager Parameters
117376-C Rev. 00
A-29
Parameter: Throughput
Path: Configuration Manager > Protocols > Frame Relay > Services > PVCs
Default: 0
Options: 0 to 2,147,483,647 b/s
Function: The rate in bits per second at which data travels over this VC when no
congestion is occurring. To enable traffic shaping, this parameter and the
Committed Burst parameter must be set to values greater than zero.
Instructions: Your carrier supplies the CIR or throughput value, which you enter in this
parameter.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.18
Parameter: Congestion Control
Path: Configuration Manager > Protocols > Frame Relay > Services > PVCs
Default: Inherit
Options: Disable
|
Enable
|
Inherit
Function: Enables or disables congestion control on this interface.
Instructions: To activate congestion control, set to Enable. This value tells the router to drop
all traffic destined for a congested PVC until the congestion clears. To
deactivate congestion control, set to Disable. If you want the Congestion
Control setting for this PVC to match the setting you specify for the frame relay
Interface Congestion Control parameter, accept the default, Inherit.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.25
Vue de la page 174
1 2 ... 170 171 172 173 174 175 176 177 178 179 180 ... 239 240

Commentaires sur ces manuels

Pas de commentaire