Site Manager Parameters
117376-C Rev. 00
A-27
To access the FR PVC List for Service window:
Site Manager Procedure
You do this System responds
1. Click on the
Protocols
menu in the
Configuration Manager menu bar.
The Protocols menu opens.
2. Click on
Frame Relay
. The Frame Relay menu opens.
3. Click on
Services
. The Frame Relay Service List window
opens.
4. Click on the
PVCs
button. The FR PVC List for Service window
opens.
Parameter: Circuit State Set
Path: Configuration Manager > Protocols > Frame Relay > Services > PVCs
Default: Active
Options: Invalid
|
Active
|
Inactive
Function: Specifies the state of the PVC.
Instructions: To indicate to a frame relay switch that the PVC is available for use, set to
Active. To indicate that the PVC is configured, but not available for use (for
example, before your switch provider actually activates the PVC), set to
Inactive. If the PVC is configured, but the switch is unaware of it, choose
Invalid.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.7
Parameter: Multicast
Path: Configuration Manager > Protocols > Frame Relay > Services > PVCs
Default: Unicast
Options: Unicast
|
Multicast
Function: Indicates whether this PVC is multicast or unicast.
Instructions: Set to Unicast or Multicast according to PVC type, as the frame relay switch
provider instructs.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.19