Site Manager Parameters
117376-C Rev. 00
A-11
SVC LAPF Parameters
If you configure SVCs, LAPF parameters are important to your network. You can
edit these parameters in the Frame Relay LAPF Parameters window (Figure A-3)
.
Parameter: Congestion Method
Path: Configuration Manager > Protocols > Frame Relay > Interfaces
Default: Shutdown
Options: Shutdown
|
Throttle
|
Throttle Then Shutdown
Function: Specifies the method of congestion control:
Shutdown - terminates the VC when congestion occurs.
Throttle - queues traffic when congestion occurs; traffic resumes when
congestion alleviates. This option is valid only when traffic shaping is
enabled.
Throttle Then Shutdown - first queues traffic when congestion occurs, and
then terminates the VC if throttling does not alleviate congestion. This
option is valid only when traffic shaping is enabled.
Instructions: Select a setting appropriate to your network.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.18