BCM50 to Mediatrix® Direct Gateway V1.0 June 2006
_______________________________________________________________________________________________________________________
18
External Distribution NORTEL
An alias must be defined on a per port basis. For this setup, only 1 port was used. Port 1 was defined with a 7
digit phone number with a type of E164 (National). This is the phone number that corresponds to the port. If the
incoming dialed phone number matches the number defined on the port and the type matches, the port will ring the
analog device. The number and type defined on the gateway corresponds to the route and destination digits that
were defined previously on the BCM50 to connect to the gateway.
Once these settings have been made, “Direct Gateway Call” button must be selected. Select “ok” when done.
Figure 14
2.4.2.5 Direct Gateway Configuration
The “Direct Gateway Call” must be defined since a gatekeeper is not being utilized. This is equivalent to the
remote gateway configuration on the BCM50.