Vue de la page 355
Configuring and Managing Routers with Site Manager
B-32
309081-14.20 Rev 00
Parameter: Fault Map
Default: CRIT
Options: EMERG
|
ALERT
|
CRIT
|
ERR
|
WARNING
|
NOTICE
|
INFO
|
DEBUG
Function: Maps router event messages with a severity level of fault to an error level
that the UNIX syslogd daemon recognizes. Table B-1
describes each of
these error levels.
Instructions: Nortel Networks recommends that you accept the default UNIX error
level for this severity level. To map this severity level to a different UNIX
error level, click on Values, and then choose the error level you want.
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.15.3.1.12
Table B-1. Error Levels for syslogd Daemon
Error Level Description
EMERG A panic condition that the syslogd daemon normally broadcasts to all
users
ALERT A condition, such as a corrupted system database, that you should
correct immediately
CRIT Critical conditions, such as hard device errors
ERR Errors
WARNING Warning messages
NOTICE Conditions that are not errors, but may require special handling
INFO Informational messages
DEBUG Messages that contain information that is of value only when you are
debugging the network