Configuring Data Compression Services
2-4
Dial Backup
PPP also allows you to configure a dial backup feature. If a primary PPP line fails
and you have enabled dial backup, the router automatically establishes a backup
line. You cannot enable any protocols, including compression, on a backup circuit,
because a backup circuit inherits its protocols from the primary circuit. If the
primary circuit uses compression, then the backup circuit does also.
For further information on Bay Networks dial services, see Configuring Dial
Services.
X.25 Services
An X.25 network permits as many as 128 VCs to exist on the same physical link at
the same time. You can configure each of those interfaces individually to use data
compression or not.
X.25 PDN and DDN Services
When you use data compression on circuits that you configure for X.25 PDN or
DDN services, you must be careful to enable compression on both sides of the
link. If you configure compression on only one side of a PDN or DDN link, the
data that travels over that link will be garbled.
You must also remember to enable the X.25 service record compression parameter
for each X.25 interface you configure. See Configuring X.25 Services for more
information about this parameter.
X.25 Max Window Size Parameter
Window size can affect packet throughput across the X.25 network. Setting the
X.25 Max Window Size parameter too low can cause the router to drop packets
and render data compression ineffective. You should configure this parameter at a
higher value than the default setting.