Installing Synchronous Net Modules in an ASN Platform
Cabling Requirements for the Net Modules6 BNX Software Version <x.x> Test Part Number
RS-422 Compliance
RS-422 compliance for the net modules is as follows:
• The Dual Sync net module requires a 44-pin D-Sub to RS-422 cable, Order
No. 7318 (Table A-5 and Figure A-3).
• The Quad Sync net module requires a 50-pin to RS-422 cable, Order No.
7937 (Table A-6 and Figure A-4).
Table A-5. Pin-to-Pin Connections for the 44-Pin D-Sub to RS-422 Cable
(Order No. 7318)
Bay Networks Termination Remote Termination
Signal Pin to Pin Signal
Data Carrier Detect- 23 31 Receiver Ready B
Data Carrier Detect+ 9 13 Receiver Ready A
Send Data+ 2 4 Send Data A
Send Data- 16 22 Send Data B
Receive Timing+ 11 8 Receive Timing A
Receive Timing- 25 26 Receive Timing B
Send Timing+ 10 5 Send Timing A
Send Timing- 24 23 Send Timing B
Receive Data+ 3 6 Receive Data A
Receive Data- 17 24 Receive Data B
Clear to Send- 19 27 Clear to Send B
Clear to Send+ 5 9 Clear to Send A
Request to Send+ 4 7 Request to Send A
Request to Send- 18 25 Request to Send B
Data Set Ready+ 6 11 DM A
Data Set Ready- 20 29 DM B
Terminal Ready+ 8 12 Terminal Ready A
Terminal Ready- 22 30 Terminal Ready B
(continued)