Router/BCC Fixed Anomalies for BayRS 15.3.0.0
Q00103090-02: Frame Relay
IP Circuit remains up after a sync interface configured with Frame Relay is disabled.
Q00153152-01: Web Server
Memory leak occurs when HTTP connections fail. This may result in an out of memory fault on the
router if this happens continuously.
Q00154341-02: ATM
Copying an ATM PVC using Site Manager gives an erroneous error message in the log message.
However, the ATM PVC is configured correctly and does come up.
Q00156640-01: ATM_PQ
Multiple attempts are required to delete ATM priority queuing.
Q00174118-01: NAT/ECMP
In a NAT with RIP2 ECMP configuration, changing between Multiple Next Hop Calculation
Methods may result in a fault on the router.
Q00135161-01: Scripts
Using install.bat to configure Frame Relay on an T1/FT1 interface will prevent Site Manager from
being able to open the configuration file. However, the router will still be able to boot using the
configuration file.
Q00152764-01: IP Traffic Filters
Enabling Extended Traffic Filter support with inbound traffic filters with user defined IP criteria
configured will cause the router to fault.
Q00173189: Radius
Memory corruption may occur when a remote Radius slot goes down.
Q00051621-03: Diffserv
Diffserv is not working for the filters that use a criteria of URL.
Q00059191-03: TI
Unable to save the configuration after many dynamic changes on very large configuration file.
Q00103537-02: Scripts
inst_pp5430.bat does not support the T3/E3 ATM PMC module.
Q00168709-01: Radius Accounting
Different session IDs are used for the Radius accounting stop and start messages for TI sessions
making it difficult to correlate the start/stop pairs for each session.
Q00174392-02: OSPF
Incorrect mask is being installed for the default router during network convergence. In redundant
topologies if there is more than one exit out of the autonomous system via a default route then
there could be a connectivity issue when the network converges due to the fact that one of the exit
points is now unavailable.
Vue de la page 0
1 2 3 4 5 6 7 8

Résumé du contenu

Page 1

1 Router/BCC Fixed Anomalies for BayRS 15.3.0.0 Q00103090-02: Frame Relay IP Circuit remains up after a sync interface configured with Frame Relay

Page 2

2 Q00175589-01: Radius The audit feature does not work for users authenticated via Radius. Q00175750-01: ATM A fault occurs when deleting an ATM s

Page 3

3 Q00209477-01: Dial Backup The ifEntry.ifOperStatus and ifSpeed attributes are incorrect if a backup circuit is configured for the interface. Q001

Page 4

4 Q00228099: PP5430 ATM T1 Bouncing an PP5430 ATM T1 interface under load may result in a fault on the router. Q00245641-01: TI The TI_INIT process

Page 5

5 Q00152897-02: ATMLANE In an ATMLANE bridging environment, after the ATM slot resets, the router does not respond to the LE_ARP from the switch cau

Page 6

6 Q00286620: Radius When the router receives incorrectly formatted Radius Authentication packets (i.e. the packet size is less than the minimum or

Page 7

7 Q00208761-01: Statistics Manager Creating a frame relay query in statistics manager using the wfCircuitShapeHiClippedPkts, wfCircuitShapeMediumCli

Page 8

8 Q00321950-01: Report Generator Report generator will not work on a 15.0.0.0 or greater configuration file that was saved on the router and copied