Site Manager WAN Line Services Parameters
117345-B Rev. 00
A-73
Parameter: Pasync Parity Type
Path: COM Connector > Edit Line > AOT > Edit SYNC Parameters
Default: Even
Options: Odd
|
Even
|
High
|
Low
|
None
Function: Sets the error-detection method for isolating altered or damaged AOT packets
during transmission. Asynchronous equipment typically adds a parity bit to the
end of a packet before transmission. This allows the receiving router to detect a
transmission error if it receives a packet with an unexpected parity.
Instructions: Click on Values and select a value that is appropriate for your network: Odd,
Even, High (1), Low (0), or None.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.116
Parameter: Pasync Data Bits
Path: COM Connector > Edit Line > AOT > Edit SYNC Parameters
Default: Eight
Options: Five
|
Six
|
Seven
|
Eight
Function: Sets the length of a polled AOT packet to a specific number of data bits.
Instructions: Click on Values and select a value that is appropriate for your network.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.117
Parameter: Pasync Stop Bits
Path: COM Connector > Edit Line > AOT > Edit SYNC Parameters
Default: Two
Options: One
|
Two
Function: Sets the interval at the end of a transmitted polled AOT packet, allowing the
receiving router to pause before accepting the next packet. More stop bits create
a longer pause at the receiving router.
Instructions: Click on Values and select a value that is appropriate for your network.
MIB Object ID: 1.3.6.1.4.1.18.3.4.5.1.118