Avaya Configuring Frame Relay Services Manuel d'utilisateur Page 107

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 162
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 106
Site Manager Parameters
117376-B Rev. 00 A-11
SVC LAPF Parameters
If you configure SVCs, LAPF parameters are important to your network. You can
edit these parameters in the Frame Relay LAPF Parameters window (F
igure A-3).
Parameter: Congestion Method
Path: Configuration Manager > Protocols > Frame Relay > Interfaces
Default: Shutdown
Options: Shutdown
| Throttle | Throttle Then Shutdown
Function: Specifies the method of congestion control:
Shutdown - terminates the VC when congestion occurs.
Throttle - queues traffic when congestion occurs; traffic resumes when
congestion alleviates. This option is valid only when traffic shaping is
enabled.
Throttle Then Shutdown - first queues traffic when congestion occurs, and
then terminates the VC if throttling does not alleviate congestion. This
option is valid only when traffic shaping is enabled.
Instructions: Select a setting appropriate to your network.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.2.1.18
Vue de la page 106
1 2 ... 102 103 104 105 106 107 108 109 110 111 112 ... 161 162

Commentaires sur ces manuels

Pas de commentaire