46 Chapter 4 Configuring the R2MFC MBM
N0027684 01
Figure 15 Config DIP switch layout
3 Power up, or restart, the R2MFC MBM.
Creating a customized country code
If the R2MFC MBM required settings are not identical to any country code, customization can be
performed using the CLI through the serial port. Perform the following steps for configuring the
customized country codes:
1 Set the Config DIP switches to match the country code closest to customer requirements. See
Appendix A, “Config DIP switch settings and definitions,” on page 85.
2 Power up or restart the BCM.
3 Make the required modifications by CLI. See Chapter 6, “Command Line Interface (CLI),” on
page 67 for an explanation of how to access and navigate the CLI.
Configuration changes made through the CLI immediately affect the operating parameters
in RAM.
Use the SaveCfg - (save configuration permanently on flash) command to save the new
settings on non-volatile Flash memory.
Note: Mexico Config 1 country code is the factory default setting. It is
the setting used if an invalid country value is set, or if a custom profile is
selected that does not exist.
ON
123456
123456
O
N
country
second
dial
tone
diagnostic
s
configuration
country