A-68 114062 Rev. B
Parameter: Congestion Counter
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface
Default: 20 notifications
Range: 1 to 500 notifications
Function: Indicates the maximum number of congestion notifications that the router can
receive during the congestion timer period before it stops transmitting. If the
router reaches the value set by this parameter, it determines the line is congested
and stops transmitting.
Instructions: Specify the congestion count. The smaller the number, the more quickly the
router detects congestion and stops transmitting. The value of this parameter
applies to all PVCs that you do not individually configure.
MIB Object ID: 1.3.6.1.4.1.18.3.5.9.9.1.1.24
Parameter: Hangup on DLCMI Failure
Path: Demand Circuits: Dialup > Demand Circuits > FR Circuits > FR Demand
Circuits > Demand Intf. > FR Demand Interface List
Backup Circuits: Dialup > Backup Circuits > Frame Relay > FR Primary
Interface Definition > Backup Def. > FR Backup Interface
Default: Disable
Options: Enable
| Disable
Function: Indicates whether to terminate the backup connection if the Frame Relay switch
does not initially respond to the call with a full status message.
Instructions: Select Enable if you want the router to clear the backup circuit when the switch
does not respond. Otherwise, accept the default.