Customizing Backup Circuits
114062 Rev. B 10-17
Removing PPP or Frame Relay Backup Service
To remove backup service:
1. Select Dialup > Backup Circuits > PPP or Frame Relay.
Site Manager displays the Primary Circuit Definition window (refer to
Figure 10-3) or the FR Primary Interface Definition window (refer to
Figure 10-4).
2. Click on either Cct Type or Intf. Type.
Site Manager displays the Circuit Options window (refer to Figure
10-2) or
the FR Interface window (refer to Figure
10-5).
3. Modify one of the following parameters:
For PPP, change the Circuit Type parameter to Normal.
For Frame Relay, change the Interface Type parameter to Normal.
Site Manager asks you to confirm the change, then removes the backup
circuit, and treats the leased circuit as a regular circuit.
4. Click on OK.
5. Click on Done.
Site Manager: Circuit Type parameter: page A-55
Site Manager: Interface Type parameter: page A-57