Part No. 114951-B Rev 00October 2000600 Technology Park DriveBillerica, MA 01821-4130Installing ATM Link Modules and Routing Engines in BN Platforms

Page 3 - Canada Requirements Only

xiFiguresFigure 1-1. Link Module Slots in a BLN Platform ...1-2Figure 1-2. Link Module Slots in a

Page 5

xiiiTablesTable 1-1. ARE DS-3 and ARE E-3 Jumper Settings ...1-6Table 3-1. Functions of the DS-3, E-3, an

Page 7

114951-B Rev 00 xv PrefaceRead this guide if you are responsible for installing any of the following Nortel Networks™ Asynchronous Transfer Mode (ATM

Page 8

Installing ATM Link Modules and Routing Engines in BN Platformsxvi 114951-B Rev 00 Text ConventionsThis guide uses the following text conventions:Ac

Page 9 - Contents

Preface114951-B Rev 00 xvii Hard-Copy Technical ManualsYou can print selected technical manuals and release notes free, directly from the Internet. G

Page 10

Installing ATM Link Modules and Routing Engines in BN Platformsxviii 114951-B Rev 00 How to Get HelpIf you purchased a service contract for your Nor

Page 11

1-1Chapter 1Installing ATM Link ModulesTo install an ATM link module, complete these preliminary tasks as needed:• Choose a slot• Remove a link module

Page 12

ii114951-B Rev 00 Copyright © 2000 Nortel NetworksAll rights reserved. October 2000.The information in this document is subject to change without noti

Page 13

Installing ATM Link Modules and Routing Engines in BN Platforms1-2114951-B Rev 00Figure 1-1. Link Module Slots in a BLN PlatformFigure 1-2. Link Modul

Page 14

Installing ATM Link Modules114951-B Rev 001-3Figure 1-3. Link Module Slots in a BCN PlatformRemoving a Link ModuleIf there are no empty slots in your

Page 15 - 114951-B Rev 00

Installing ATM Link Modules and Routing Engines in BN Platforms1-4114951-B Rev 00Removing a link module with the power on distrupts the services that

Page 16 - Acronyms

Installing ATM Link Modules114951-B Rev 001-5Figure 1-4. Jumpers on the ARE DS-3 Link ModuleBefore installing the ARE DS-3 or E-3 link module, refer t

Page 17 - Hard-Copy Technical Manuals

Installing ATM Link Modules and Routing Engines in BN Platforms1-6114951-B Rev 00Inserting the Link ModuleInsert the link module in the BLN, BLN-2, or

Page 18 - How to Get Help

Installing ATM Link Modules114951-B Rev 001-7Figure 1-5. Link Module Captive Screws (BCN Example)4.Once you are done accessing the interior of the cha

Page 20 - Captive screws

2-1Chapter 2Installing ARE Processor ModulesTo install an ARE processor module, you must first1. Remove the front bezel of your BN platform.2. Remove

Page 21 - Removing a Link Module

Installing ATM Link Modules and Routing Engines in BN Platforms2-2114951-B Rev 00Removing the Front BezelYou must remove the BN platform front bezel (

Page 22 - Configuring Jumper Settings

Installing ARE Processor Modules114951-B Rev 002-3Figure 2-2. Removing the BLN-2 Front BezelTo remove the front bezel from the BCN (Figure 2-3):1.Usin

Page 23

114951-B Rev 00iiiEC Declaration of ConformityThis product conforms (or these products conform) to the provisions of Council Directive 89/336/EEC and

Page 24 - Inserting the Link Module

Installing ATM Link Modules and Routing Engines in BN Platforms2-4114951-B Rev 00Figure 2-3. Removing the Front Bezel from the BCNPOWERRUNBOOTDIAGB A

Page 25

Installing ARE Processor Modules114951-B Rev 002-5Removing the EMC ShieldYou must remove the EMC shield to access the processor modules in BN platform

Page 26

Installing ATM Link Modules and Routing Engines in BN Platforms2-6114951-B Rev 00Figure 2-4. BLN and BCN EMC ShieldsPOWERRUNBOOTDIAGB A C K B O N E N

Page 27 - Chapter 2

Installing ARE Processor Modules114951-B Rev 002-7Choosing a SlotYou can install the ARE processor module in• Slots 2 through 5 in the BLN platform (F

Page 28 - Removing the Front Bezel

Installing ATM Link Modules and Routing Engines in BN Platforms2-8114951-B Rev 00Figure 2-6. Location of Processor Modules and the SRM-F in a BLN-2 Pl

Page 29 - ALM0011A

Installing ARE Processor Modules114951-B Rev 002-9Figure 2-7. Location of Processor Modules and the SRM-F in a BCN PlatformSRM-FPOWERRUNBOOTDIAGB A C

Page 30 - Pull top

Installing ATM Link Modules and Routing Engines in BN Platforms2-10114951-B Rev 00Removing the Board Retainer Bracket (BLN and BLN-2 Only)If you have

Page 31 - Removing the EMC Shield

Installing ARE Processor Modules114951-B Rev 002-11Figure 2-9. Removing an Air Flow ModuleRemoving a Processor Module To remove a processor module:1.G

Page 32

Installing ATM Link Modules and Routing Engines in BN Platforms2-12114951-B Rev 00Figure 2-10. Using the Extractors to Remove a Processor ModuleInsert

Page 33 - Choosing a Slot

Installing ARE Processor Modules114951-B Rev 002-134.If you just installed the ARE processor module in a BLN or BLN-2 platform, replace the board reta

Page 34 - Platform

iv114951-B Rev 00Canada Requirements Only (continued)Repairs to certified equipment should be coordinated by a representative designated by the suppl

Page 36 - Removing an Air Flow Module

3-1Chapter 3Checking Status IndicatorsCheck the LEDs on the ATM link modules or the ARE processor module to verify that a module is operating after in

Page 37 - Removing a Processor Module

Installing ATM Link Modules and Routing Engines in BN Platforms3-2114951-B Rev 00Figure 3-2. ARE SONET/SDH Link Module LEDsTable 3-1 describes the LED

Page 38 - FRE0005A

Checking Status Indicators114951-B Rev 003-3ARE Processor LEDsFigure 3-3 shows the ARE processor LEDs, as well as the following:• Harpoon Diagnostic C

Page 39

Installing ATM Link Modules and Routing Engines in BN Platforms3-4114951-B Rev 00Table 3-2. ARE Processor LEDs LED DescriptionGroup 11 (Green) The ARE

Page 40

Checking Status Indicators114951-B Rev 003-5LEDs 14 and 15 in Group 3 (refer to Figure 3-3) indicate the diagnostic test that is currently executing.

Page 42 - SONET/SDH

114951-B Rev 00vFCC Part 68 Compliance StatementThis equipment complies with Part 68 of FCC Rules. All direct connections to telephone network lines m

Page 43 - ARE Processor LEDs

vi114951-B Rev 00Nortel Networks NA Inc. Software License AgreementNOTICE: Please carefully read this license agreement before copying or using the a

Page 44

114951-B Rev 00viifor the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct lost

Page 46

ixContents PrefaceText Conventions ...........................xviAc

Commentaires sur ces manuels

Pas de commentaire