Using Technician Interface Software
2-14 117381-A Rev. A
Parameter: Command Timeout
Attribute Name: wfSerialPortCommandTimeOut
Attribute Number: 18
Default: 15 min
Options: 1 to 99 min (99 indicates infinity)
Function: Specifies the number of minutes that can elapse before the Technician
Interface disconnects the Telnet session, if you do not enter a command at
the command prompt. This parameter is valid only when Modem Enable
is set to 1 (Enable).
Instructions: Accept the default value (15 minutes) or specify a different timeout value.
Command:
set wfSerialPortEntry.18.
<port_no.> <option>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.11.1.1.18
Parameter: Login Retries
Attribute Name: wfSerialPortLoginRetries
Attribute Number: 19
Default: 3 login attempts
Options: 1 to 99 (99 indicates infinity)
Function: Specifies the maximum number of login attempts you can make before
the Technician Interface disconnects the Telnet session. This parameter is
valid only when Modem Enable is set to 1 (Enable).
Instructions: Accept the default value (3) or specify a different value.
Command:
set wfSerialPortEntry.19.
<port_no.> <option>
MIB Object ID: 1.3.6.1.4.1.18.3.3.2.11.1.1.19