Avaya Using Technician Interface Scripts Manuel d'utilisateur Page 693

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 849
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 692
Using Technician Interface Scripts
2-646 117380-A Rev. A
Sample Display - show t1 alerts
T1 Modules on Alert:
--------------------
Frame Line B8ZS Clock
Slot Conn Circuit Type Bldout Support Mode MiniDacs Configuration
---- ---- ------- ----- ------ ------- -------- ------------------------
2 1 T1-21 ESF 1 Off Internal 1111111111111111IIIIIIII
2 2 T1-22 ESF 1 Off Slave 2222222222222222IIIIIIII
Found 2 matches out of 2 entries in table.
base [circuit
<circuit name>
]
Displays the base level information for all T1 circuits or a specific circuit. For definitions
of the columns in the table, see the
alerts command.
Sample Display - show t1 base
T1 Modules:
-----------
Frame Line B8ZS Clock
Slot Conn Circuit Type Bldout Support Mode MiniDacs Configuration
---- ---- ------- ----- ------ ------- -------- ------------------------
2 1 T1-21 ESF 1 Off Internal 1111111111111111IIIIIIII
2 2 T1-22 ESF 1 Off Slave 2222222222222222IIIIIIII
2 entries in table.
Vue de la page 692
1 2 ... 688 689 690 691 692 693 694 695 696 697 698 ... 848 849

Commentaires sur ces manuels

Pas de commentaire