Obtaining site plans
Obtain two scaled plans. The scale is required to check wiring distances from the controller to
the basestations. The scale is in the form of a measured line so that it remains in proportion
to the floor plan through reduction copiers.
Figure 21: Example of a site coverage floor plan
Obtaining site plans
Obtain two site plans/maps, with dimensions marked.
One working copy to identify critical points, cell centres, and cell boundaries. One clean
copy to attach to the site Provisioning Record for the installer
, customer, or
maintenance.
Gathering building information
Gather the following information and enter it into the work-order.
Gathering building information
1. Obtain building identification.
Record this information.
2. Obtain information on construction materials, such as walls, floors, ceilings.
Record this information.
3. Note the type of use of facilities, such as office, hotel, factory, store.
Record this information.
4. Find the number of floors.
Site survey
DMC DECT Fundamentals August 2012 55