Figure 94: DMC8/DMC8-E jumper details
See Installing DMC8 and DMC8-E in an IPE shelf on page 163 for card jumper settings.
Caution:
Service Interruption
Ensure that the DMC8/DMC8-E Relay card jumpers J6 to J9 are in the ETH position for
operation on a dedicated LAN.
Ensure that the DMC8/DMC8-E Relay card jumpers J6 to J9 are in the V
.24 position for
operation on a serial connection to the DMC DECT Manager server.
Installing DMC8 and DMC8-E in an IPE shelf
1. Install J1 jumper straps on the DMC8 and the DMC8-Es for Card ID.
For pre-Release 23 software, strap A B. For post-Release 23 software, and Multi-
Site Mobility Networking, strap B C.
2. Install J2 jumper straps on the DMC8 and the DMC8-Es for the system type.
Strap A B for IPE shelf.
3. Install J3 jumper straps on the DMC8 and the DMC8-Es for cabinet or IPE shelf
number.
Installing DMC8 and faceplate cables
DMC DECT Fundamentals August 2012 163