Configuring ATM Services
1-4 114056 Rev. A
3. Change the Data Encapsulation Type parameter from LANE (the
default) to LLC/SNAP, NLPID, or NULL.
4. Change the Virtual Connection Type parameter from SVC to PVC.
Refer to Appendix A for a detailed description of any parameter you may
want to customize.
5. Click on OK.
The Select Protocols window opens.
6. Go to “Enabling Protocols on an ATM Service Record,” later in this
chapter.
Adding a Service Record for Classical IP
To add a service record for Classical IP:
1. Click on Service Attributes in the Edit ATM Connector window.
The ATM Service Records List window opens.
2. Click on Add.
The ATM Service Record Parameters window opens.
Note: If you disabled signaling in the Initial ATM Signaling Config window,
the ATM Service Record Parameters window automatically changes the
default for the Data Encapsulation Type parameter to Logical Link Control/
Subnetwork Access Protocol (LLC/SNAP) and the Virtual Connection Type
parameter to PVC.
Note: For an explanation of the different data encapsulation types, and rules
for assigning data encapsulation, refer to Chapter 2.
Note: You must press the return key or tab key to advance to the Virtual
Connection Type parameter. Pressing either key acknowledges the data
encapsulation type selection. If you neglect this step, the Configuration
Manager does not provide PVC as an option for the Virtual Connection Type
parameter.