Avaya Configuring ATM Services Manuel d'utilisateur Page 192

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 268
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 191
Configuring ATM Services
A-42 114056 Rev. A
Parameter: Max Number of SVC Applications
Path: Configuration Manager > Protocols > ATM > ATM Signaling
(This parameter also appears in the Initial ATM Signaling Config window.)
Default: 20
Options: 1 through 32767
Function: Identifies the maximum number of service access points (SAPs) allowed for this
circuit. The number of SAPs corresponds to the number of LAN emulation or IP
(RFC 1577) clients allowed for the circuit.
Instructions: Accept the default, 20, or enter a value from 1 through 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.6
Parameter: Max Point to Point Connections
Path: Configuration Manager > Protocols > ATM > ATM Signaling
(This parameter also appears in the initial ATM Signaling Config window.)
Default: 1000
Options: 0 through 32767
Function: Identifies the maximum number of simultaneous point-to-point connections
allowed for this circuit.
Instructions: Accept the default, 1000, or enter a value from 0 through 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.7
Parameter: Max Point to Multipoint Connections
Path: Configuration Manager > Protocols > ATM > ATM Signaling
(This parameter also appears in the Initial ATM Signaling Config window.)
Default: 40
Options: 0 through 32767
Function: Identifies the maximum number of simultaneous point-to-multipoint
connections allowed for this circuit.
Instructions: Accept the default, 40, or enter a value from 0 through 32767.
MIB Object ID: 1.3.6.1.4.1.18.3.4.23.1.7.1.8