BCM Rls 6.0 Redundancy Task Based Guide

Page 2 - All Rights Reserved

Redundancy 10 NN40011-048 Issue 1.2 BCM450 Rls 6.0 3. Grasp the fan connector at the plug and pull to undo the connection. 4. Next, remove a

Page 3

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 11 5. The fan is held in place with plastic (two piece) grommets. Simply pull the pin out of t

Page 4 - Table of Contents

Redundancy 12 NN40011-048 Issue 1.2 BCM450 Rls 6.0 1. First, grasp the connectors and gently pull to remove the two plugs that connect the power s

Page 5

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 13 3. Once disconnected, remove all associated retaining screws for the power supply at th

Page 6 - RAID Keycode

Redundancy 14 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Note: You may require a cutting tool to assist in breaking the connection struts of

Page 7 - Flowchart

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 15 Removing the Front Hard Drive Cover The final preparation task is to remove the Front Hard Drive

Page 8 - Installation

Redundancy 16 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Completed Pre-Preparation Check List Upon completion ensure that you have removed:  The curre

Page 9 - Removing the Fan

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 17 Installing the Redundancy & RAID Kit For the purpose of this guide, we will install the foll

Page 10

Redundancy 18 NN40011-048 Issue 1.2 BCM450 Rls 6.0 1. Starting with the first unit, ensure the fan label is the right way up (power

Page 11 - Removing the Power Supply

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 19 3. Rest the fan faceplate on top of the unit (ensure that the lip of the facepl

Page 12

Redundancy 2 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Copyright © 2010 Avaya Inc. All Rights Reserved. Notices While reasonable efforts have been made

Page 13

Redundancy 20 NN40011-048 Issue 1.2 BCM450 Rls 6.0 5. Perform the same procedure for the second fan. 6. Both units should now be fixed to th

Page 14

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 21 7. Secure the faceplate to the chassis with the fixing screws. 8. Finally, clip both powe

Page 15

Redundancy 22 NN40011-048 Issue 1.2 BCM450 Rls 6.0 9. Your secondary fan is now installed alongside the original unit. Installing the Redundant

Page 16

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 23 1. Begin by removing the PSU Status jumper on the Chassis Interface Card. 2.

Page 17

Redundancy 24 NN40011-048 Issue 1.2 BCM450 Rls 6.0 3. Now that the plate has been removed, you can position the power supply as shown.

Page 18

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 25 5. Tidy away the cables as necessary, separating the same four leads that will connec

Page 19

Redundancy 26 NN40011-048 Issue 1.2 BCM450 Rls 6.0 7. Next, reconnect the two leads that will power the MBM’s. 8. Once completed, your connec

Page 20

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 27 9. You can now reseat the BCM 450 access panel and secure with the retaining screws. 10. The

Page 21

Redundancy 28 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Installing the Secondary Hard Disk Drive Installing a secondary Hard Disk Drive (for RAID

Page 22

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 29 3. The secondary Hard Disk Drive is now installed. Replace the front Hard Drive cover and tight

Page 23

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 3 Downloading documents For the most current versions of documentation, see the Avaya Support. Web

Page 24

Redundancy 30 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Note: The Disk Mirroring option only becomes visible after RAID keycode entry. 2. If the Ad

Page 25

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 31 3. Click on the drop down list to change the status, and click OK. 4. Click OK to the secon

Page 26

Redundancy 32 NN40011-048 Issue 1.2 BCM450 Rls 6.0 LED States HDD-1 LED RAID LED HDD-2 LED Description Green Green Green - BCM completed booting,

Page 27

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 33 Avaya Documentation Links  Troubleshooting Guide  Installation – System  Maintenance

Page 28

Redundancy 4 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Table of Contents Redundancy ...

Page 29

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 5 Redundancy Overview This guide will cover the installation procedures required to instal

Page 30

Redundancy 6 NN40011-048 Issue 1.2 BCM450 Rls 6.0 RAID Keycode Note: If installing the RAID kit, ensure that the RAID Keycode is showing as act

Page 31

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 7 Flowchart This flowchart depicts the steps necessary to upgrade a BCM 450 with a redu

Page 32

Redundancy 8 NN40011-048 Issue 1.2 BCM450 Rls 6.0 Preparing the BCM 450 for Redundancy Kit Installation Before installing a Redundancy kit, th

Page 33 - Avaya Documentation Links

Redundancy NN40011-048 Issue 1.2 BCM450 Rls 6.0 9 Removing the Fan To install the secondary fan and cover plate, the existing components need to be