Media Bay Modules
NN40011-003 Issue 1.2 BCM450 Rls 6.0 41
Attribute
Value
Module/line type
600-700 feet
Set the distance between BCM and an external channel service unit. This setting only
appears when the Internal CSU is Disabled. Contact your service provider for the proper
settings.
CRC4
<check box>
E1
PRI
Ensure this is enabled or disabled to match the service provider Cyclic Redundancy
Check (CRC4) setting for the trunk.
DASS2 Modules
1. Configure the options as required.
DASS2 Module-Specific Settings
Attribute
Value
Module / Line Type
Clock
Source
Primary External Secondary External
Internal
*
*
DASS2
Designates whether the DTM/BRI acts as a primary or secondary timing component for an
external timing source or as the internal timing source.
Note: A BRI module can be programmed with primary/secondary clock source, however, it
is recommended that a BRI module always be set to Internal if a DTM exists on the system
to be the Primary External clock source.
Warning: Changing the clock source may disconnect calls.
If you change the clock source for your system, you may cause your system DTM
interface(s) to reset, resulting in dropped calls. Choose a suitable time to change the clock
source and use the Page feature to inform users of possible service disruptions.