Avaya Digital Enchanced Cordless Telecommuncations SIP DECT Fundamentals Manuel d'utilisateur Page 77

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 254
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 76
Single and multiple floor deployment 77
Figure 45
Multi-cell distance
Procedure 16
Multi-cell deployment
Step Action
1 Choose a position on the floor plan for the cell center that meets
the following requirements.
a is furthest from the critical points and still provides good audio
quality at the critical point,
b complies with the “Rules and guidelines to locate cell centers”
(page 35), and
c is in the coverage area.
2 Place the deployment tool at critical point P1.
3 Establish a link.
4 Walk briskly into the coverage area away from the critical point
until the cell boundary is reached.
5 Mark a small X on the floor plan where the cell boundary is
found.
6 Repeat step 4 and 5 several times, walking in different directions
from the critical point to establish an arc. The arc is at the cell
boundary and is within range of the critical point.
7 Draw a thin contour line to mark an arc through the Xs on the
floor plan.
8 Repeat steps 4 through 7 walking into the coverage area of
critical point P2.
9 Locate the cell center on the arc along a line from the critical
point that is equal distant from the adjacent walls.
Nortel Communication Server 1000
SIP DECT Fundamentals
NN43120-123 01.07
6 January 2009
Copyright © 2008-2009 Nortel Networks
.
Vue de la page 76
1 2 ... 72 73 74 75 76 77 78 79 80 81 82 ... 253 254