Networking Configuration Guide
Chapter 14
Configuring lines: T1-Loop start
Loop start trunks provide remote access to the BCM from the public network. They must be
configured to auto-answer to provide remote system access. A loop start trunk must have
disconnect supervision if it is to operate in the auto-answer mode.
The following paths indicate where to access the loop start trunks information through Element
Manager and through Telset Administration:
Element Manager: Configuration > Telephony > Lines
Telset interface: **CONFIG > Lines
Prerequisites
Complete the following prerequisites checklist before configuring the modules.
Process map
Figure 47, Figure 48, and Figure 49 provide an overview of the configuration process for T1-Loop
start lines.
Task: Configure the analog or digital loop start lines connected to the system.
“Configuring digital (T1/E1) loop start lines” on page 161
Analog or DTM module is installed and configured. Refer to “Trunk
Module Parameters” on page 104.
Lines are provisioned. Refer to “Provisioning module lines/loops” on