Avaya Configuring BayStack Remote Access Manuel d'utilisateur Page 57

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 168
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 56
Configuring Netboot Services with Site Manager
117341-A Rev. A 3-3
Table 3-1 lists the module names for BayStack AN configurations.
a. AN DSU/CSU interfaces do not support network booting.
Table 3-1. BayStack AN Configurations
Base AN Interface
Configuration Optional Components Site Manager Module Name
1 Ethernet (XCVR1), 1 token
ring (TOKEN1), and 2
synchronous (COM1 and
COM2)
None E/T/2S
1 ISDN BRI (replaces COM2) E/T/2S/BRI
1 third synchronous interface E/T/3S
1 ISDN BRI with floating B channel E/T/2S/BRI+
1 Ethernet DCM E/T/2S/N11 DCM
1 ISDN BRI with floating B channel and
1 Ethernet DCM
E/T/2S/BRI+/N11 DCM
1 third synchronous interface and
1 Ethernet DCM
E/T/3S/N11 DCM
1 DSU/CSU interface
a
E/T/2S/DSU
1 Ethernet (XCVR1) and
2 synchronous (COM1 and
COM2)
None E/2S
1 ISDN BRI (replaces COM2) E/2S/BRI
1 ISDN BRI with floating B channel E/2S/BRI+
1 Ethernet DCM E/2S/N11 DCM
1 third synchronous interface E/3S
1 second Ethernet interface 2E/2S
1 third synchronous interface and
1 Ethernet DCM
E/3S/N11 DCM
1 ISDN BRI with floating B channel and
1 Ethernet DCM
E/2S/BRI+/N11 DCM
1 second Ethernet interface and
1 Ethernet DCM
2E/2S/N11 DCM
1 DSU/CSU interfacea
2E/2S/DSU
1 token ring (TOKEN1) and
2 synchronous (COM1 and
COM2)
None T/2S
1 ISDN BRI (replaces COM2) T/2S/BRI
1 ISDN BRI with floating B channel T/2S/BRI+
1 third synchronous interface T/3S
1 DSU/CSU interfacea
T/2S/DSU
Vue de la page 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 167 168

Commentaires sur ces manuels

Pas de commentaire