Avaya R5.0: Guide de configuration Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
BCM Rls 5.0 Configuration Guide For: MTS/Allstream SIP Trunking
2009-00002508 Page 12 of 20
2. Add a “Remote Gateway” by clicking on the “Add” button.
3. In the “Add Remote Gateway” dialog box that is displayed, configure the fields as follows:
Description: Enter the logical name for the trunk destination
Destination Digits: Enter digits that identify the remote system as the call destination.
VoIP Protocol: SIP
Domain: SIP Domain name of MTS/Allstream. This will be provided by MTS/Allstream.
IP Address: Provide the IP address of the SBC. This will be provided by MTS/Allstream.
Port: Provide the optional UDP port number to which the BCM will send SIP messages.
GW Type: Set this field to Other.
MCDN Protocol: Set to None.
QoS Monitor: Leave unchecked
Tx Threshold: Leave this field at its default value of 0.0
4. Click the OK button
Vue de la page 11