Site Manager Line Services Parameters
114078 Rev. A A-35
Parameter: Max T2 Acknowledge Timer (seconds)
Path: COM Connector for X.25 Interface > Edit Line > LAPB > Edit LAPB
Parameters
Default: 1 second
Options: 1 to 9999 seconds
Function: Specifies the time, in seconds, that the router waits before sending an
acknowledgment for a sequenced frame. A value of 1 means that the router does
not delay before generating an acknowledgment.
Instructions: Enter the amount of time that you want the router to wait before acknowledging
a frame.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.8.1.13
Parameter: Max T3 Disconnect Timer (seconds)
Path: COM Connector for X.25 Interface > Edit Line > LAPB > Edit LAPB
Parameters
Default: 60 seconds
Options: 1 to 9999 seconds
Function: Specifies the time, in seconds, that the router waits before determining that the
link is disconnected. A value of 1 indicates that once the router completes the
frame exchange to bring down the link, it considers the link disconnected.
Instructions: Enter the amount of time that you want the router to wait before it decides that
the link is disconnected.
MIB Object ID: 1.3.6.1.4.1.18.3.5.1.8.1.14