D-4 114079 Rev. B
Parameter: BOFL Timeout Divisor
Default: 1 (10 when the interface is configured for Router Redundancy)
Options: An integer 1 to 59, less than or equal to the value of the BOFL Timeout
parameter
Function: The BOFL Timeout parameter specifies a time period between
transmissions of Breath of Life messages from this Ethernet interface.
Beginning with Router Software Version 11.01, the actual time between
BOFL transmissions is the value of the BOFL Timeout parameter divided
by the value of the BOFL Timeout Divisor parameter. When set to a value
greater than 1, this parameter reduces the value of BOFL Timeout.
When you configure Router Redundancy on an interface, Site Manager
automatically sets this parameter to reduce the time between BOFL
transmissions. If the circuit goes down, the interface reaches the BOFL
Retries value sooner, thus reducing the time it takes the router to declare a
circuit down.
Instructions: Increase the value of this parameter if you want line status to be detected
in less than 1-second intervals.
For example, with the BOFL Timeout parameter set to 5 seconds and the
BOFL Timeout Divisor set to 10, the router sends a BOFL message
every 0.5 seconds (5 divided by 10). With BOFL Timeout set to 5 seconds
and the BOFL Timeout Divisor set to 1, transmissions occur every 5
seconds.