Configuring Ethernet, FDDI, and Token Ring Services
2-4
305259-A Rev 00
Enabling or Disabling an Ethernet Interface
The router enables CSMA/CD services when you add a 10 Mb/s or 100 Mb/s
Ethernet circuit to the router configuration file.
You can disable and enable the Ethernet interface without moving physical
cabling.
Using the BCC
To enable the Ethernet interface, access an existing Ethernet line service and
enter:
enable
To disable the Ethernet interface, access an existing Ethernet line service and
enter:
disable
For example, to enable an Ethernet interface, enter the following command
sequence:
box#
ethernet slot 13 connector 1
ethernet/13/1#
enable
Using Site Manager
To enable or disable an Ethernet interface, complete the following tasks:
Site Manager Procedure
You do this System responds
1. In the Configuration Manager window,
choose an
XCVR
Connector.
The Edit Connector window opens.
2. Choose
Edit Line
. The Edit CSMA/CD Parameters window
opens.
3. Set the
Enable
parameter. Click on
Help
or see the parameter description on
page A-2
.
4. Click on
OK
. You return to the Edit Connector window.
5. Click on
Done
. You return to the Configuration Manager
window.