Avaya Configuring Ethernet, FDDI, and Token Ring Services Manuel d'utilisateur Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 156
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
Getting Started
308623-14.00 Rev 00
1-3
back
back
tokenring slot 9 connector 1
circuit-name O91
speed 4Meg
ip address 192.168.2.1 mask 255.255.255.0
arp
back
rip
back
back
back
To access line services, at the top-level box prompt use the output from the show
config -all
command and enter:
<interface_type>
slot <
slot_number>
connector <
connector_number
>
For example, to access the Ethernet line services on slot 13, connector 1, navigate
to the top-level box prompt and enter the following command:
box# ethernet slot 13 connector 1
To display the current values for the Ethernet line services, enter the following
command:
ethernet/13/1# info
on box
state enabled
circuit-name E131
slot 13
connector 1
bofl enable
bofl-timeout 5
hardware-filter disable
transmit-queue-length 0
receive-queue-length 0
bofl-retries 5
bofl-tmo-divisor 1
bofl-number 0
interface_type
Name of a physical interface on the router
slot_number
Number of the slot on which the link module is located
connector_number
Number of a connector on the link module