BayRS Version 14.00Part No. 308617-14.00 Rev 00September 19994401 Great America ParkwaySanta Clara, CA 95054Configuring BSC Transport Services

Page 3

308617-14.00 Rev 00xiTablesTable A-1. Device Address Table for BSC3 ... A-1Table C-1. Inter

Page 5 - Contents

308617-14.00 Rev 00xiiiPrefaceThis guide describes how to configure router software to transport binary synchronous communication (BSC) data over a mu

Page 6

Configuring BSC Transport Servicesxiv308617-14.00 Rev 00Text ConventionsThis guide uses the following text conventions:angle brackets (< >) Indi

Page 7

Preface308617-14.00 Rev 00xvAcronymsThis guide uses the following acronyms:Hard-Copy Technical ManualsYou can print selected technical manuals and rel

Page 8

Configuring BSC Transport Servicesxvi308617-14.00 Rev 00You can purchase selected documentation sets, CDs, and technical publications through the coll

Page 9

308617-14.00 Rev 001-1 Chapter 1Starting BSC Transport ServicesThe quickest way to begin using BTS is to enable it with default values for all Bisync

Page 10

Configuring BSC Transport Services1-2308617-14.00 Rev 00Starting BTSTo start BTS on an interface, select the synchronous connector on which you are en

Page 11 - 308617-14.00 Rev 00

308617-14.00 Rev 002-1 Chapter 2BSC Transport Services OverviewBTS transmits binary synchronous communication (BSC) data over a multiprotocol backbone

Page 12

ii308617-14.00 Rev 00 Copyright © 1999 Nortel NetworksAll rights reserved. Printed in the USA. September 1999.The information in this document is subj

Page 13 - Before You Begin

Configuring BSC Transport Services2-2308617-14.00 Rev 00There are two main versions of the BSC protocol:• BSC3, Interactive (BSC 3270)Its primary-seco

Page 14 - Text Conventions

BSC Transport Services Overview308617-14.00 Rev 002-3 Figure 2-1. Tunneling of BSC FramesBSC data travels between two routers using a process called t

Page 15 - Hard-Copy Technical Manuals

Configuring BSC Transport Services2-4308617-14.00 Rev 00Point-to-Point and Multipoint ConfigurationsYou can use BTS with point-to-point, multipoint, a

Page 16 - How to Get Help

BSC Transport Services Overview308617-14.00 Rev 002-5 Figure 2-3. BTS Multipoint ConfigurationVirtual Multipoint ConfigurationIn a virtual BTS multipo

Page 17 - Chapter 1

Configuring BSC Transport Services2-6308617-14.00 Rev 00Figure 2-4. BTS Virtual Multipoint ConfigurationTCP/IP HostFEPCU CUCUCUCU CUCUCUCU CUCUCUSeco

Page 18 - Starting BTS

308617-14.00 Rev 003-1 Chapter 3Implementation NotesThis chapter describes basic guidelines for implementing BTS on your network.BTS InterfacesYou can

Page 19 - Chapter 2

Configuring BSC Transport Services3-2308617-14.00 Rev 00When you assign a peer router, you must specify • The IP address of the peer router• Which of

Page 20 - Hosts and Control Units

Implementation Notes308617-14.00 Rev 003-3 Line DetailsConfiguring line details for a bisynchronous line is similar to configuring line details for a

Page 22 - Multipoint Configuration

308617-14.00 Rev 004-1 Chapter 4Configuring BTSWhen you enable BTS, default values are in effect for all parameters (see Appendix C). You can change t

Page 23 - BTS0004A

308617-14.00 Rev 00iiiNortel Networks NA Inc. Software License AgreementNOTICE: Please carefully read this license agreement before copying or using t

Page 24 - BTS0005A

Configuring BSC Transport Services4-2308617-14.00 Rev 00Accessing BTS ParametersIn Site Manager, either of these paths leads you to the BTS parameters

Page 25 - Implementation Notes

Configuring BTS308617-14.00 Rev 004-3 Customizing BTS InterfacesYou can edit the BTS settings on individual interfaces to perform the following tasks:

Page 26 - Connections to Control Units

Configuring BSC Transport Services4-4308617-14.00 Rev 00Creating Primary and Secondary ConnectionsThe Interface Attached To parameter specifies whethe

Page 27 - Line Details

Configuring BTS308617-14.00 Rev 004-5 Enter a value appropriate for the network in the range 0 to 86400 seconds. We recommend that you set this parame

Page 28

Configuring BSC Transport Services4-6308617-14.00 Rev 00Deleting a BTS InterfaceTo delete a BTS interface from its associated physical circuit, follow

Page 29 - Configuring BTS

Configuring BTS308617-14.00 Rev 004-7 Selecting the Connection OriginatorWhen you configure a connection, you need to decide which router initiates th

Page 30 - Accessing BTS Parameters

Configuring BSC Transport Services4-8308617-14.00 Rev 00Enabling and Disabling BTS Peer ConnectionsWhen you configure a peer router, the local router

Page 31 - Customizing BTS Interfaces

Configuring BTS308617-14.00 Rev 004-9 Entering the Control Unit AddressThe control unit address is a hexadecimal value in the range 0x40 to 0xFE. For

Page 32 - Selecting an Interface Type

Configuring BSC Transport Services4-10308617-14.00 Rev 00Editing Line ParametersThis section describes the parameters you can modify for each BTS line

Page 33

Configuring BTS308617-14.00 Rev 004-11 Adjusting the Bisynchronous Timing SignalsThe Clock Source parameter specifies the origin of the bisynchronous

Page 34 - Assigning Peer Routers

iv308617-14.00 Rev 00for the security of its own data and information and for maintaining adequate procedures apart from the Software to reconstruct

Page 35 - Setting the TCP Listen Ports

Configuring BSC Transport Services4-12308617-14.00 Rev 00Accept the default value (0) or enter a value in the range 0 to 255 that is appropriate for t

Page 36

308617-14.00 Rev 00A-1 Appendix AControl Unit AddressesTo specify a connection to a control unit, you enter the control unit’s address. Table A-1 show

Page 37

Configuring BSC Transport ServicesA-2308617-14.00 Rev 0017 0xD118 0xD219 0xD320 0xD421 0xD522 0xD623 0xD724 0xD825 0xD926 0x5A27 0x5B28 0x5C29 0x5D30

Page 38 - Editing Line Parameters

308617-14.00 Rev 00B-1 Appendix BBTS ParametersBTS Global ParametersBTS Interface ParametersParameter: EnablePath: Configuration Manager > Protocol

Page 39

Configuring BSC Transport ServicesB-2308617-14.00 Rev 00Parameter: Interface Attached ToPath: Configuration Manager > Protocols > BOT > Inter

Page 40

BTS Parameters308617-14.00 Rev 00B-3 Parameter: TCP Keepalive Int (sec)Path: Configuration Manager > Protocols > BOT > InterfacesDefault: 120

Page 41 - Control Unit Addresses

Configuring BSC Transport ServicesB-4308617-14.00 Rev 00BTS Peer Table ParametersParameter: TCP Keepalive Retry Count Path: Configuration Manager >

Page 42 - (continued)

BTS Parameters308617-14.00 Rev 00B-5 Parameter: Connection OriginatorPath: Configuration Manager > Protocols > BOT > Interfaces > Peer Tab

Page 43 - BTS Parameters

Configuring BSC Transport ServicesB-6308617-14.00 Rev 00BOT CU Table ParametersParameter: Control Unit AddressPath: Configuration Manager > Protoco

Page 44

BTS Parameters308617-14.00 Rev 00B-7 Line ParametersParameter: EnablePath: Configuration Manager > Select connector > Edit LineDefault: EnableOp

Page 45

308617-14.00 Rev 00vContents PrefaceBefore You Begin ...

Page 46 - BTS Peer Table Parameters

Configuring BSC Transport ServicesB-8308617-14.00 Rev 00Parameter: Clock SpeedPath: Configuration Manager > Select connector > Edit LineDefault:

Page 47

BTS Parameters308617-14.00 Rev 00B-9 Parameter: Control Character ModePath: Configuration Manager > Select connector > Edit LineDefault: EBCDIC

Page 49 - Line Parameters

308617-14.00 Rev 00C-1 Appendix CDefault Values for BTS ParametersTables C-1 through C-4 list the Site Manager default parameter settings for BTS.Tabl

Page 50

Configuring BSC Transport ServicesC-2308617-14.00 Rev 00Table C-3. Control Unit ParametersParameter DefaultControl Unit Address NoneEnable EnableTable

Page 51

308617-14.00 Rev 00Index-1Aacronyms, xvassigning peer routers, 3-1, 4-6BBOT (Bisync over TCP)control unit connection parametersControl Unit Address, 4

Page 52

Index-2308617-14.00 Rev 00DdeletingBTS from all circuits, 1-2BTS on an interface, 4-6disablinga Bisync line, 4-10, B-7connections to control units, 4-

Page 53 - Appendix C

308617-14.00 Rev 00Index-3RRTS Enable parameter, 4-12, B-9SSerial adapter module, 1-1, 3-1, 4-1specifying connections to control units, 3-2, 4-8starti

Page 55

vi308617-14.00 Rev 00Chapter 4 Configuring BTSUsing the MIB Object ID ...

Page 56

308617-14.00 Rev 00viiAppendix A Control Unit AddressesAppendix B BTS ParametersBTS Global Parameters ...

Page 58

308617-14.00 Rev 00ixFiguresFigure 2-1. Tunneling of BSC Frames ..................2-3Figure 2-2

Commentaires sur ces manuels

Pas de commentaire